Vacuum Chamber Slit and Hardware
Looking for a domestic source. This means that the country of origin is USA. Not just manufacturing but also raw materials must be from the USA. Vacuum Chamber Slit - 1 Each - Technical Specs below Cables between customers feedthrough and controller (10 meters) Technical Specifications Aperture size: Maximum: 7 mm x 7 mm; Minimum: Full overlap. Resolution: Aperture: 0.813 microns per full step; Translation: 0.322 microns per full step. Repeatability: < 1 micron. Accuracy: ± 3 microns (over 3 mm). VacuumO-ring sealed, high vacuum 10-5 mbar, low outgassing materials. Standard blades:2 mm thick tungsten carbide blades with a 2 degrees knife-edge profile. Limit switches (end-of-travel) Included as standard on all motions. Guiding: High precision internal rails and carriages. Electrical connections: Limit switches coupled to 2 motor connectors (SUB-D 15 pins male). Motors: 2-phase stepping motors; Mechanical dimensions: 145 mm x 145 mm x 80 mm; Mechanical connections: M6-threaded holes on the sides, as shown on the drawing, and KF-40 flange connections are on the body of both sides of the slit; Weight: ≈ 1.6 kg; Outer surface: Anodized aluminum in color nature; Common options. Blades: Other blade shapes and materials. Adaptors: KF50 or CF40 flange connections. Special preparation for enabling vacuum <10-6 mbar. Internal wiring with Teflon insulation.
Key dates
Response due
August 24, 2026
- Posted
- August 19, 2026
Details
- Agency
- Argonne Natl Lab - Doe Contractor
- Buyer type
- Federal
- Jurisdiction
- the United States (US)
- Category
- Clinical
- Value
- —
- Set-aside
- —
- NAICS
- 334516
- PSC
- 6640
- Source
- sam.gov
Who is this buyer
Organization
Source: Provider universeNot matched to a provider record yet.
Buying history
Source: Solicitation records- Records14 total
- Opportunities / awards12 / 0
- ActiveJuly 21, 2026 – August 19, 2026
What they buy
- Clinical (14)
Set-asides used
- No Set aside used (6)
Financial highlights
Source: IRS Form 990No 990 filing on record.
Who holds their work today
Source: Solicitation records · awardsNo awards on record for this buyer.
What they're trying to solve
Source: AI-generatedNo brief written for this buyer yet.
Also open from this buyer
Source: Solicitation records- Polished Beryllium Window CartridgeDue September 2, 2026 · Clinical
- APS VFD MigrationDue August 23, 2026 · Clinical
- 352-MHz/160kW SOLID STATE RF POWER SYSTEM FOR APS BOOSTER SYSTEMSDue August 31, 2026 · Clinical
- Prototype X-undulator Vacuum ChamberDue August 31, 2026 · Clinical
Ways to meet this buyer
Source: Solicitation records · event noticesUpcoming
No upcoming events on record.
View source document →
Source link on sam.gov.